  Hydraulic breaker is a commonly used tool for breaking hard materials such as concrete and rock. During use, nitrogen leakage sometimes occurs, which may affect work efficiency and safety. Therefore, it is very important to deal with nitrogen leakage in time.

  1. When nitrogen leakage is found, it should be stopped immediately and placed in a well-ventilated place away from fire and flammable materials. Then, check whether the nitrogen supply pipeline and joints are loose or damaged. If so, they should be repaired or replaced in time.

  2. Soapy water or gas leak detector can be used to detect the location of nitrogen leakage. Spray soapy water or gas leak detector on the nitrogen supply pipeline and joint of the breaker. If there is nitrogen leakage, bubbles or odor will be generated. This method can quickly and accurately find the location of nitrogen leakage.

The role of nitrogen in hydraulic breaker

  3. Once the location of the nitrogen leak is determined, it can be repaired or replaced. If the leak is caused by loose nitrogen supply pipeline or joint, it can be tightened with a wrench or spanner. If the leak is caused by damage to the nitrogen supply line or joint, you need to replace it with a new nitrogen supply line or joint.

  4. After repairing or replacing the nitrogen supply line or joint, you need to perform a nitrogen leak test to ensure that the repaired or replaced parts are not leaking. You can use soapy water or gas leak detector to test again to ensure that no bubbles or odors are generated.

  5. You can restart the equipment and conduct a test run to ensure that the nitrogen leakage problem has been solved. During use, you should also regularly check the nitrogen supply line and joints to ensure that they are working properly and avoid nitrogen leakage again.

  In general, handling nitrogen leakage in hydraulic breakers requires timely discovery and rapid processing to ensure work efficiency and safety. Through the above methods, the problem of nitrogen leakage in the equipment can be effectively solved to ensure the smooth progress of work.